23/10/2023
If you are involved in the HVAC&R Industry, manufacturer or distributor and need your product to be tested and certified. Efectis Era Avrasya can help you to better understand the standard requirements and specifications to determine the fire performance according to various international standardizations ‘’EN, BS, UL’’.
The primary standards that Efectis Era Avrasya offers for fire resistance testing are;
1- For fire and smoke control ducts according to the following European and British standards:
EN 1366-1: Fire Resistance Tests For Service Installations- Ventilation Ducts
EN 1366-8: Fire resistance tests for service installations – Part 8: Multi-compartment Smoke extraction ducts
EN 1366-9: Fire resistance tests for service installations – Part 9: Single compartment smoke extraction ducts
EN 1366-12: Fire resistance tests for service installations – Part 12: Non-mechanical fire barrier for ventilation ductwork
BS 476-24: Fire tests on building materials and structures-Method for determination of the fire resistance of ventilation ducts
2- For powered smoke and heat exhaust ventilators according to the following European standards:
EN 12101-3 (Annex C and Annex D)
3- For natural smoke and heat exhaust ventilators according to the following European standards:
EN 12101-3: Smoke and heat control systems – Part 3: Specification for powered smoke and heat exhaust ventilators (Annex C and Annex D)
4- For fire and smoke control dampers according to the following European and American standards:
EN 1366-2: Fire resistance tests for non-loadbearing installations- Part 2: Fire dampers
EN 1366-10: Fire resistance tests for service installations- Part 10: Smoke control dampers
UL 555: Standard for Fire Dampers- Fire Endurance and Hose Stream Tests
UL 555 S: Standard for Smoke Dampers- Cycling, Leakage and Fire Endurance Tests
Efectis also offers certifications for the above product categories:
UL 555 C: Standard for Ceiling Dampers- Closing Reliability and Fire Endurance Tests
CE marking for ductworks according to EN 12101- Part 7 in the content of CPR.
CE Marking for Fire alarm/detection, fixed fire-fighting, fire and smoke control, and explosion suppression products (1/1):- Powered ventilators (fire safety) according to EN 12101- Part 3 in the the content pf CPR.
CE Marking for Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1): – Dampers (fire safety) according to EN 15650 &EN 12101-8
CE Marking for Smoke and heat control systems according to EN 12101- Part 2: Specification for natural smoke and heat exhaust ventilators
Certificates of Compliance (CoC’s): for United Arab Emirates, Kingdom of Saudi Arabia, Qatar, Kuwait, Kingdom of Bahrain and Sultanate of Oman.
For further information, please contact: sihem.belhassani@efectis.com