20/4/2021

Efectis has recently carried out a series of tests to evaluate the fuel source to develop a method harmonized at European level to assess the fire performance of façade.

A series of tests were carried out to evaluate the heat exposure of the test specimen, using different configurations of wood cribs according to their characteristics and using two type of fire exposure – high and medium exposure – in accordance with DIN 4102-20 and BS 8414 standards respectively.

Since different parameters are used such as the amounts of fuel, type of fuel, shape of combustion chamber, and the ventilation conditions, and since extremely limited data is available on the heat exposure of the test specimen, it is not possible to compare the different test methods. Therefore, the choice has been made to keep the heat source and all related specifications as per BS 8414 series and DIN 4102-20.

The heat source has been installed into the same combustion chamber so that the impact of such environment on the fire behaviour is considered. To assess the influence of the system on the facade, a portion of non-combustible facade was installed above the combustion chamber.

To ensure that the selected method has good enough repeatability and reproducibility, the test programme investigated variations in the main parameters as described below:

For each test, a series of measurements and calculations have been performed to characterise each crib:

The main purpose of these tests was to obtain an answer to several questions, allowing the assessment method to be finalised before the experimental round-robin starts.

Contact: Talal Fateh – talal.fateh@efectis.com